    The SLE-MAXAI-FIRE from Napco is a sole/dual path alarm communicator specifically designed to interface with FACP (Fire Alarm Control Panels) and operates on the AT&T network utilizing CAT-M1 technology. 

    Features:

    • Electrical Ratings for +12V / 24V (powered by the control panel)†
    • Input Voltage: 10-24VDC regulated (power-limited output from Certified control panel Aux/Remote Fire Power)
    • Input Current: 10VDC standby: 115mA 12VDC standby: 101mA 15VDC standby: 92mA 24VDC standby: 85mA Wi-Fi Module: (Optional) Add 45mA to the above. (With peak RF transmission current of 325mA). Electrical Ratings for the IN 1 Fire Input:
    • Input Voltage: 9-25VDC.
    • Maximum Input Current: Up to 2mA from FACP NAC circuit Electrical Ratings for IN 2, IN 3, IN 4, and IN 5: (Inputs IN 2, IN 3, IN 4, and IN 5 are Class B)
    • Maximum Loop Voltage: 25VDC input.
    • Maximum Loop Current: 1.7mA
    •  Antenna Length: 8.25" (21cm) Environmental
    • Operating Temperature: 0°C - 49°C (32°F - 120°F)
    • Humidity: Maximum 93% Non-Condensing
    • Indoor / dry location use only

    The SLE-MAXAI-FIRE from Napco is a sole/dual path alarm communicator specifically designed to interface with FACP (Fire Alarm Control Panels) and operates on the AT&T network utilizing CAT-M1 technology. 

    Features:

    • Electrical Ratings for +12V / 24V (powered by the control panel)†
    • Input Voltage: 10-24VDC regulated (power-limited output from Certified control panel Aux/Remote Fire Power)
    • Input Current: 10VDC standby: 115mA 12VDC standby: 101mA 15VDC standby: 92mA 24VDC standby: 85mA Wi-Fi Module: (Optional) Add 45mA to the above. (With peak RF transmission current of 325mA). Electrical Ratings for the IN 1 Fire Input:
    • Input Voltage: 9-25VDC.
    • Maximum Input Current: Up to 2mA from FACP NAC circuit Electrical Ratings for IN 2, IN 3, IN 4, and IN 5: (Inputs IN 2, IN 3, IN 4, and IN 5 are Class B)
    • Maximum Loop Voltage: 25VDC input.
    • Maximum Loop Current: 1.7mA
    •  Antenna Length: 8.25" (21cm) Environmental
    • Operating Temperature: 0°C - 49°C (32°F - 120°F)
    • Humidity: Maximum 93% Non-Condensing
    • Indoor / dry location use only